View A This type of winding is used in dc generators designed for high-current applications. The windings are connected to provide several parallel paths for current in the armature. For this reason, lap-wound armatures used in dc generators require several pairs of poles and brushes.In lap winding, the finishing end of one coil is connected to a commutator segment and to the starting end of the